Function, rubber sheet according to a use Non-Conductive Rubber Sheet

Features
- ・Excels in high-voltage resistance.
Applications
- ・For high-voltage equipment.
Function | ・ Antistatic Property |
---|
*Hardness measurement is revised to “After 3 seconds” according to JIS K 6253 (2006). However, generally, the conventional "measurement within 1 second" is to be the mainstream for nominal hardness, so this result is measured value and the measurement result after 3 seconds is shown in ().
Properties: Non-Conductive Rubber Sheet
Item Name | Properties | |||||
---|---|---|---|---|---|---|
General Properties | Breakdown Voltage kV/mm |
Material | ||||
Hardness Type A |
Tensile Strength at Break MPa{kgf/cm2} |
Elongation at Break % |
||||
Black N/C (M) Sheet | 60(60) | 11.1 {113} | 530 | 22.6 | NR (Black) | |
Amber Rubber Sheet (60%) | <45> | 47(47) | 19.1 {195} | 680 | 18.6 | NR (Amber) |
TAB 6007 SO2 | 60(58) | 14.3 {146} | 650 | 22.0 | W/R NR (Black) | |
N/C EPT Sheet | <40> | 40(39) | 10.3 {105} | 660 | 15.0 | EPT (Black) |
<50> | 51(48) | 11.9 {121} | 560 | 21.2 | EPT (Black) | |
<65> | 61(60) | 10.0 {102} | 600 | 22.1 | EPT (Black) | |
TNB 9012 S | 90(88) | 15.0 {153} | 340 | 7.4 | NBR (Black) | |
SR-50 | <50> | 51(51) | 10.3 {105} | 410 | 16.7 | SR (Natural) |
FR Sheet | <80> | 78(75) | 10.5 {107} | 360 | 2.2 | FR (Black) |
- JIS K 6250
- ●Allowable voltage should be regarded approx. 1/3 of the breakdown voltage only as a guide.
- ●The above mentioned FR Sheet <80> is not "TBF8010", but non-conductive FR sheet.
- *N/C: Non-Conductive W/R: Whether Resistance
Please check here to find out the environmental compliance of this product.
●These descriptions can be altered for a reason of improvement without any notification.
●These descriptions shall be as of November 1, 2021.
Inquiry for Details of Our Products
Product specifications, dimensions, and designs are subject to change without notice due to improvements, etc.